+1.65 errors
more errors made by students in high-CO₂ classrooms
Higher CO₂ levels (2115 ppm vs 1045 ppm) significantly increased student error rates by 1.65
A cross-over cluster-randomised study across 20 mechanically ventilated classrooms compared two CO₂ conditions: 'worse' averaging 2115 ppm and 'better' averaging 1045 ppm, on separate days each week. Using the d2 concentration test with 2366 test results from 417 third- and fourth-grade students, hierarchical regression found no significant change in overall concentration performance or characters processed, but the total number of errors rose significantly by 1.65 (95% CI 0.42-2.87) under the worse condition.
For those responsible for classroom ventilation and indoor air quality, this suggests that even when CO₂ levels do not visibly slow down how much work students complete, accuracy may still suffer at higher concentrations. This points toward CO₂ control in schools as a factor worth weighing when aiming to reduce careless errors, though the pathway from CO₂ to error-making itself is not established here.
The confidence interval, 0.42 to 2.87, is fairly wide and close to zero at its lower bound, and the same study found no significant effect on overall performance or output volume, so the error result stands somewhat apart from the rest of the data. The design is a controlled crossover trial in real classrooms with children of a specific age group, so it does not generalise beyond that setting without care.
Education
TE was increased significantly by 1.65 (95% confidence interval 0.42-2.87) in 'worse' compared to 'better' condition.
Used in these factorsheets
CO₂ concentration probably lowers sustained attention.
Related studysheets
+26.3%
worse decision-making with more indoor fine particle pollution
A 10 μg/m³ rise in indoor PM2.5 increases the probability of making an erroneous chess move by 26.3%
Steffen Künn et al., 2019, SSRN Electronic Journal
+26.3%
higher chance of making a bad chess move when fine particle air pollution rises
A 10 µg/m³ rise in indoor PM2.5 increases the probability of making an erroneous move by 26.3%
Steffen Künn et al., 2023, Manag. Sci.
elevated CO2 reversed the microgravity-induced speed-accuracy tradeoff
Exposure to 0.5% CO2 reversed the response strategy changes induced by head-down tilt bed rest
Mathias Basner et al., 2018, Journal of applied physiology
Read more in
Education Which classroom conditions affect learning
Where the evidence on classroom air, acoustics, light and green is strong, where it is thin, and what to measure before the build.
Workplace Why open-plan offices break concentration
In open plan the work staff say they lose to noise can double, and speech intelligibility predicts it better than the sound level.
Workplace